NICET ITFAS-Level-1 Exam Overview:
| Certification Vendor: | NICET |
| Exam Name: | Inspection and Testing of Fire Alarm Systems Level I |
| Exam Number: | ITFAS-Level-1 |
| Passing Score: | 500/700 |
| Exam Format: | Multiple-choice, Multiple-select, Hotspot |
| Real Exam Qty: | 85 |
| Available Languages: | English |
| Related Certifications: | NICET Inspection and Testing of Fire Alarm Systems Level II |
| Exam Price: | USD 230 |
| Exam Duration: | 110 minutes |
| Certificate Validity Period: | 3 years |
| Sample Questions: | NICET ITFAS-Level-1 Sample Questions |
| Exam Way: | Computer-based test (CBT) at Pearson VUE Testing Centers or online remote proctoring (OnVue). |
| Pre Condition: | Minimum of 6 months of experience in the inspection and testing of fire alarm and suppression interfaces. |
| Official Syllabus URL: | https://www.nicet.org/certification-programs/electrical-and-mechanical-systems/inspection-and-testing-of-fire-alarm-systems |
NICET ITFAS-Level-1 Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| Test Equipment | 24-34% | - Test notification appliances and circuits - Test initiating devices and circuits - Test control equipment and circuits - Test off-premises signaling equipment and circuits - Test basic interfaces - Manually measure sensitivity of detectors (without accessing site-specific programming) |
| Inspect Equipment | 24-34% | - Inspect initiating devices (e.g., smoke detectors, heat detectors, manual pull stations) - Inspect basic interfaces - Inspect control equipment (e.g., fire alarm control panels, power supplies) - Inspect off-premises signaling equipment - Inspect notification appliances (e.g., horns, strobes, speakers) |
| Plan and Coordinate Work | 7-17% | - Determine the number, type, and location of devices to be inspected and/or tested - File documentation and reports - Identify findings and issue appropriate notifications to applicable parties - Issue notifications to applicable parties of testing and completion as needed - Coordinate with the owner/building manager during inspection and testing - Restore the system - Identify and apply the appropriate inspection and testing requirements for the job |
| Maintain Devices | 3-13% | - Replace batteries as needed - Clean devices as needed - Identify replacement devices as needed |
NICET Inspection and Testing of Fire Alarm Systems Level I Sample Questions:
1. What is the maximum extended interval allowed for equipment to get inspected?
A) 18 months
B) 6 months
C) 3 months
D) 12 months
2. Which of the following is the inspection frequency of the candela rating of visible appliances?
A) Initial acceptance and if a malfunction occurs
B) Initial acceptance and no further inspections
C) Initial acceptance and semiannually
D) Initial acceptance and quarterly
3. After 15 years from initial installation, all fixed-temperature, nonrestorable heat detectors shall be replaced or have how many detectors per 100 laboratories tested?
A) 2
B) 8
C) 6
D) 4
4. In addition to 10% of devices not affected, what else must be tested when site-specific software is changed?
A) 10% of devices affected
B) 50% of devices affected
C) 25% of devices affected
D) 100% of devices affected
5. In private mode systems, what is the audibility requirement?
A) Minimum 85 dBA
B) 15 dBA above ambient
C) 10 dBA above ambient
D) Minimum 75 dBA
Solutions:
| Question # 1 Answer: D | Question # 2 Answer: A | Question # 3 Answer: D | Question # 4 Answer: D | Question # 5 Answer: C |